Chapter Page
------- ----
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . 1
2. HOST - HOST Procedures . . . . . . . . . . . . . . . . . . 2
2.1 Generalities . . . . . . . . . . . . . . . . . . . . 2
2.2 Connections and Links . . . . . . . . . . . . . . . . 2
2.2.1 Definitions . . . . . . . . . . . . . . . . . 2
2.2.2 Connection types . . . . . . . . . . . . . . . 3
2.3 Message Structure . . . . . . . . . . . . . . . . . . 5
2.4 User Transactions . . . . . . . . . . . . . . . . . . 6
2.4.1 List of transactions . . . . . . . . . . . . 7
2.4.2 HOST-HOST protocol and control messages . . . 8
3. Implementation in GORDO . . . . . . . . . . . . . . . . . 11
3.1 Introduction to GORDO . . . . . . . . . . . . . . . . 11
3.1.1 GORDO file system . . . . . . . . . . . . . . 11
3.1.2 GORDO process . . . . . . . . . . . . . . . . 12
3.2 Software Organization Overview . . . . . . . . . . . 12
3.3 Software Description . . . . . . . . . . . . . . . . 13
3.3.1 Data structures . . . . . . . . . . . . . . . 13
3.3.1.1 Allocation tables . . . . . . . . . . 13
3.3.1.2 Buffer pages . . . . . . . . . . . . 16
3.3.2 Programs . . . . . . . . . . . . . . . . . . . 18
3.3.2.1 Handler . . . . . . . . . . . . . . . 18
3.3.2.2 Network . . . . . . . . . . . . . . . 19
3.4 Software Procedures . . . . . . . . . . . . . . . . . 20
3.4.1 Description of some typical sequences . . . . 20
Appendix A: Flowcharts . . . . . . . . . . . . . . . . . . . 23
[[RFC Editor Note: [s] represents subscript s]]
1. INTRODUCTION
This technical note concentrates upon (1) the HOST-HOST procedures
and (2) the implementation of the corresponding programs in GORDO
(Operating System of the UCLA HOST).
Deloche [Page 1]
RFC 11 Host - Host Software Procedures in GORDO August 1969
The first section is closely related to the BBN reports No. 1822 and
1763[1] and specifies the HOST functions for exchanging messages. It
mostly deals with links and connections, message structure,
transactions, and control messages.
The second section is software oriented; it explains how the HOST
functions are implemented and integrated into GORDO. It is involved
with data structures, programs, buffers, interrupt processing, etc.
[1] Parts of this section are taken from or referred to those
reports.
2. HOST-HOST PROCEDURES
2.1 Generalities
The basic idea is that several users, at a given HOST, should
simultaneously be able to utilize the network by time-sharing its
physical facilities.
This implies that within each HOST operating system, there must exist
a special program that multiplexes outgoing messages from the users
into the network and distributes incoming messages to the appropriate
users. We will call this special program the Network program.
2.2 Links and Connections (See figure 1)
2.2.1 Definitions
It is convenient to consider the Network as a black box - a system
whose behavior is known but whose mechanisms are not - for
communicating messages between remote users rather than between pairs
of HOST computers.
(a) Logical connections
We define a logical connection as being a communication path
linking two users at remote HOST[s].
With that concept, a user (user program) in a HOST computer can
(1) establish several logical connections to any remote HOST
users, and (2) send or receive messages over those connections.
Connections appear to users as full duplex.
One of the purposes of the Network program is to serve the
users in establishing, identifying, and maintaining these
connections.
Deloche [Page 2]
RFC 11 Host - Host Software Procedures in GORDO August 1969
(b) Logical links
Each logical connection is made of a pair of directional links:
one for transmitting, the other for receiving.
Those links, called logical links, are established by the
Network programs and used by them.
Note here that users are only interested in connections and are
completely unaware of links. Relationships between links and
connections are carried out by the Network program.
One of the advantages to define a connection as a pair of
directional links is that a HOST will have the capability to
loop himself through its IMP (it opens a connection to
himself). This feature can be useful for debugging purposes.
Further on through this paper we will not use any more the
attribute logical when referring either to links or
connections.
2.2.2 Connection types
In order to reach a high flexibility in utilizing the Network there
is advantage to classify the connections.
Three types of connections are distinguished: (a) control
connection, (b) primary connection, and (c) auxiliary connection.
(a) Control connection
This connection has a special status and is unique between a pair
of HOST[s], e.g., if the Network includes x HOST[s], there are at
most x control connections issued from one HOST.
This connection is used by remote Network programs for passing
control messages back and forth. Control messages are basic to
the establishment/deletion of standard connections. (See 2.4.2)
Note here that this control connection is the only connection
which is not used by the HOST users.
Let us describe now the standard connections.
Deloche [Page 3]
RFC 11 Host - Host Software Procedures in GORDO August 1969
(b) Primary connection
These connections connect remote users.
A primary connection:
* Is unique between a pair of users and is the first to be
established.
* Is "teletype-like", i.e.:
- ASCII characters are transmitted;
- Echoes are generated by the remote HOST;
- The receiving HOST[s] scan for break characters;
- The transmission rate is slow (less than 20
characters/sec).
* Is mainly used for transmitting control commands, e.g.,
for log-in into a remote HOST operating system.
(c) Auxiliary connection
These connections also connect remote users:
An auxiliary connection:
* Is opened in parallel to a primary connection and is not
unique, i.e., several auxiliary connections can be
established between users.
* Is used for transmitting large volumes of data (file
oriented).
* Is used either for binary or character transmission.
[Figure 1 - Links and Connections - see PDF file]
Deloche [Page 4]
RFC 11 Host - Host Software Procedures in GORDO August 1969
2.3 Message Structure
The HOST[s] communicate with each other via messages. A message may
vary in length up to 8095 bits (See down below the structure).
Larger transmission must therefore be broken up by HOST users into a
sequence of such messages.
A message structure is identified on figure 2.
It includes the following:
(1) A leader (32 bits): Message type, Source/Destination HOST,
link number. (See BBN report No. 1822, pp 13, 17)
(2) A marketing (32 bits when sent by the Sigma 7) for starting a
message text on a word boundary. (See BBN report No. 1822,
pp. 17, 19)
(3) The message text (Max: 8015 bits for the Sigma 7). It mostly
consists of user's text. However, it may represent
information for use by the Network programs. (Control
messages, see 2.4.2)
(4) A checksum (16 bits). Its purpose is to check, at the HOST
level, the right transmission of a message. (Changes in bit
pattern or packet transposition; packets are defined in BBN
report No. 1763, p. 13) See down below for checksum
calculation.
(5) A padding for solving word length mismatch problems. (See BBN
report No. 1822, p. 17, 19.). As far as software is
concerned, padding is only involved at message reception for
delineating message ends. (At transmission the hardware takes
care of the padding.)
Remark:
Checksum calculation:
The last 16 bits of every message sent by a HOST is a checksum.
This checksum is computed on the whole message including any
marking, but excluding the 32 bit leader and any padding. To
compute the checksum:
1. Consider the message to be padded with zeroes to a length of
8640 bits.
2. Section the 8640 bits into six 1440-bit segments, S0, S1...S5.
Deloche [Page 5]
RFC 11 Host - Host Software Procedures in GORDO August 1969
3. Section each 1440-bit segment S into 90 16-bit elements, T0,
T1...T89.
4. Define a function [(+)], which takes two 16-bit elements as
inputs and outputs a 16-bit element. This function is defined
by
Tm [(+)] Tn = Tm [(+)] Tn, if Tm + Tn < 2[exp 16]
Tm [(+)] Tn = Tm [(+)] Tn - 2[exp 16] + 1, if Tm + Tn >= 2[exp
16]
5. For each 1440-bit segment Si compute Ci = K(Si), where
K(S) = T0 [(+)] T1 + ..... T89
6. Computer C =
C0[(+)]C1[(+)]C1[(+)]C2[(+)]C2[(+)]C2[(+)]C2....[(+)]C5
(Notice that C1[(+)]C1 is just C1 rotated left one bit)
The number C is the checksum. The reason the Ci are rotated by i
bits is to detect packet transposition.
[Figure 2 - Format of a message sent by the Sigma 7 - see PDF file]
2.4 User Transactions
From what has been discussed until here, the Network appears to a
user as a bunch of connections. Let us now explain how one can make
use of these connections.
First, we are going to describe the set of transactions that a user
should be able to access for utilizing the connection facilities.
Then, we are going to explain the role of the Network program for the
execution of these transactions. This will cover a HOST-HOST
protocol in which control messages are exchanged between network
programs.
For explanation purposes those transactions are represented, at the
user level, in the form of subroutine calls and parameters. However,
this does not imply at all that the implementation will closely
follow this pattern. (We are more involved here with the description
than the implementation aspect, see chapter 3.)
Deloche [Page 6]
RFC 11 Host - Host Software Procedures in GORDO August 1969
2.4.1 List of transactions
Listed below are the descriptions of subroutines that could be at
user's disposal for creating/breaking connections and
transmitting/receiving data over them. This set of subroutines can
be considered as a kind of interface between the user level and the
network program level.
(a) Open primary connection:
OPENPRIM (CONNECTID, HOSTID, BUFFADDR, [OPT])
CONNECTID: Connection identification #
HOSTID: Remote HOST identification #
BUFFADDR: Buffer address for incoming messages.
OPT: Options such as message required after successful
connection establishment, "full echo" (each message is
transmitted back by the remote HOST for checking purpose),
etc.
Remark: [ ] means optional
(b) Open auxiliary connection
OPENAUX (CONNECTID, BUFFADDR, N, [OPT])
CONNECTID: Connection identification #, i.e., the
identification of the corresponding primary
connection (First a user has to open a primary
connection).
BUFFADDR: Same meaning as above.
N: Number of auxiliary connections that should be opened.
OPT: Same meaning as above.
(c) Transmission over connection
TRANSM (CONNECTID, NO, BUFFADDR, N, [OPT])
CONNECTID: Connection identification #
NO: Connection #. The primary connection is always referred to
as being NO=0. An auxiliary connection number corresponds
to the order in which it has been established. (The first
auxiliary opened is referred to by NO=1, the second by
NO=2, etc.)
BUFFADDR: Buffer address of the message to be transmitted.
N: Message size (byte number)
OPT: Options such as data type (characters vs. binary), trace
bit, etc.
Deloche [Page 7]
RFC 11 Host - Host Software Procedures in GORDO August 1969
(d) Close connection
CLOSE (CONNECTID, [N], [NO])
CONNECTID: Connection identification #.
N: Number of connections to be closed. If omitted all
connections in use by the user, included the primary link,
are closed.
NO: In case of N different from zero this number indicates the
auxiliary connection # to be closed.
2.4.2 HOST-HOST protocol and control messages
The HOST-HOST protocol is carried out by the Network programs. It
mainly involves the execution of the previous transactions (initiated
by users) and covers a HOST-HOST dialogue.
This dialogue fulfills control procedures for opening or breaking
connections and consists in exchanging control messages over the
control link. A control message has a structure identical to that of
a regular message; it only differs from it by the text which is for
use by Network programs instead of users.
Let us insist that this control procedure is completely unrelated to
transmission control procedures implemented in the IMP computers. We
are here at the HOST level (Network programs), and therefore control
messages, that are going to be described below, are transmitted over
the IMP[s] like regular messages.
Consider now the previous transactions and describe for each of them
which messages are exchanged over which links. Each case will be
explained by means of trivial examples.
We suppose that a HOST(x) user wants to a remote HOST(y) program
called URSA.
(a) Open a primary connection: (OPENPRIM)
The HOST (x)'s Network program, waken up (See 3.3) by a use for
opening a primary connection, starts a dialogue with the HOST
(y)'s Network program.
(i) HOST(x) sends the following control message:
HOST(x) Control link HOST(y)
-------------------->
ENQ PRIM 0 1 2
Deloche [Page 8]
RFC 11 Host - Host Software Procedures in GORDO August 1969
ENQ: Enquiry for connection establishment (one ASCII
character)
PRIM: Connection type: primary (one special character)
0 1 2: Outgoing link #. It is a decimal number (3 ASCII
characters), e.g., link #12.
This link # has been determined by the HOST(x)
Network program (See implementation: 3.3)
(ii) HOST(y) acknowledges by sending back the following control
message:
HOST(x) Control link HOST(y)
<------------------------
ACK ENQ PRIM 0 1 2 0 1 5
ACK: Positive acknowledgment (one ASCII character)
ENQ PRIM 0 1 2: Same meaning as above. This part of the
message is returned for checking purposes.
0 1 5: Incoming link #. It follows the same pattern as
the outgoing link #. This link # has been
determined by the HOST(y) Network program.
Now the connection is established; it will use
links #12 and 15 for exchanging user messages.
The connection is said to be in a pre-log-in
state, i.e., the remote HOST(y) expects its
standard log-in procedures.
(b) Transmission over primary connection: (TRANSM)
By means of TRANSM subroutines referring to the primary
connection, the HOST(x) user is able to sign-in into the
HOST(y) operating system and then to call for the URSA program
(HOST(y) user program).
The Network programs at both ends will use the link #12 and #15
for passing along messages. These messages are standard
messages whose contents serve for log in sequence.
A trivial example could be:
HOST(x) Prim. Link #12 HOST(y)
---------------------------->
! S I G N - I N : X X
Deloche [Page 9]
RFC 11 Host - Host Software Procedures in GORDO August 1969
HOST(x) Prim. Link #15 HOST(y)
<--------------------------
! ! R E A D Y
HOST(x) Prim. Link #12 HOST(y)
---------------------------->
! U R S A
(c) Open an auxiliary connection: (OPENAUXI)
In a very similar manner as (a) an auxiliary connection is
established between HOST(x) and HOST(y). For so doing control
messages are exchanged over the control link.
HOST(x) Control link HOST(y)
------------------------------>
ENQ AUX 0 2 5
HOST(x) Control link HOST(y)
<--------------------------------
ACK ENQ AUX 0 2 5 0 2 1
Now the auxiliary connection is established, it will use links
#25 and 21 for exchanging standard messages.
(d) Transmission over auxiliary connection: (TRANSM)
By means of TRANSM subroutines referring to the auxiliary
connection, the users at both ends can exchange data:
HOST(x) Aux. Link #25 HOST(y)
-------------------------------->
X X ..... X X
HOST(x) Aux. Link #21 HOST(y)
<--------------------------------
X ......... X
etc.......
(e) Close connections: (CLOSE)
This is carried out in a similar manner as (a). The user calls
a CLOSE subroutine and then the Network programs at both ends
exchange control messages.
Deloche [Page 10]
RFC 11 Host - Host Software Procedures in GORDO August 1969
HOST(x) Control Link HOST(y)
----------------------------->
EOT 0 0 1 0 1 2
EOT: End of transmission (one ASCII character)
0 0 1 : No. of connections to be closed (3 decimal ASCII
characters)
0 1 2 : Outgoing link # to be closed.
Then HOST(y) acknowledges back as in (a).
HOST(x) Control Link HOST(y)
<-----------------------------
ACK EOT 0 0 1 0 1 2 0 1 5
Remark 1 - In (a), (c), and (e) HOST(y) may answer back a
message including a negative acknowledgement character NAK
instead of ACK. This for many various reasons such as: wrong
sequence, connection already opened, and so forth. The message
could be NAK IND, where IND is an alphanumerical character
indicating, in a coded form, why the previous block has been
refused. Upon receiving back such acknowledgments HOST(x) will
repeat its message until HOST(y) accepts it. An emergency
procedure will take place if too many successive "NAK messages"
occur.
Remark 2 - On each of the above illustrations (arrows) only the
message text is represented. In fact, complete messages (with
leader, marking, padding...) are exchanged over these links.
3. IMPLEMENTATION IN GORDO
3.1 Introduction to GORDO
GORDO is a time-sharing system implemented on SDS Sigma 7. We
outline below some of the characteristics relevant to our paper.
3.1.1 GORDO file system
The file system is page oriented. It is composed of files and
directories. A file consists of a heading and a number of pages
which compose the body of the file. A directory consists of a number
of entries that point to either files or other directories.
Deloche [Page 11]
RFC 11 Host - Host Software Procedures in GORDO August 1969
3.1.2 GORDO process
* A process is a program (procedures and data) plus its logical
environment. In other words a process is a program which is known
and controlled by the GORDO scheduler.
* A user (a job) may have several processes as different as
compiler, loader, editor, application program, etc. A process is
created through a system call (FORK).
* The space a process can refer to is the Virtual Space of 128k word
length. A part (8k) of it is reserved for the operating system,
the other part (120k) is directly accessed by the user. This
later may fill or modify its part of the virtual space upon
'coupling'. (See below: service calls) pages taken from different
files. Figure 3 illustrates this coupling.
* A process can request for services by means of system calls. The
system calls relevant to our paper are:
WAKE for awaking (set active) a sleeping process
SLEEP for putting asleep another process (or itself)
COUPLE for coupling a page from the file space to the virtual
space.
* A process ordinarily runs in slave mode. However if it is set up
as an I/O process it can access privileged instructions.
* Processes can share data through files attached to "mail box"
directories.
Remark: Through this note the words process and program are used
inter-changeably.
[Figure 3 - Virtual Space and Coupling - see PDF file]
3.2 Software Organization Overview
Figure 4 illustrates the overall organization.
The system is based upon two main programs: the "Network" and the
"Handler".
The Handler is an I/O interrupt routine closely related to the IMP-
HOST hardware interface. It serves the Network process in
transmitting an receiving network messages.
The Network process carries out most of the work.
Deloche [Page 12]
RFC 11 Host - Host Software Procedures in GORDO August 1969
Its main function is to satisfy the users' requests for opening/
closing connections and transmitting/receiving network messages. For
so doing,
* it establishes, identifies, and breaks the links upon using the
allocation tables (HOST, CONNECT, INPUT LINK; see 3.3.1.1)
* it is aware of the presence of new users upon exploring the
Network mail box directory;
* it communicates with active users by means of shared pages through
which messages and requests are exchanged (connection shared
pages);
* it formats incoming/outgoing messages in a working page. This
working page has an extension (emergency ring);
* it communicates with the Handler by means of a shared page (I/O
communication page) which contains the I/O communication buffers.
[Figure 4 - Software organization overview - see PDF file]
3.3 Software Description
3.3.1 Data Structures
3.3.1.1 Allocation tables: HOST, CONNECT, INPUT LINK
The Network program establishes, identifies, and breaks links and
connections upon using 3 tables:
A table sorted by remote HOST #.
A table sorted by connection #.
A table sorted by input link #.
(a) HOST table (see figure 5)
It is a bit table indicating the free outgoing links. It
has the following characteristics:
* Location: Disc resident
* Coupling: Coupled to the Network process virtual space.
* Size: As many slots as remote HOST[s].
Deloche [Page 13]
RFC 11 Host - Host Software Procedures in GORDO August 1969
* Slot structure: As many bits as possible outgoing links
to a remote HOST, i.e., 256.
* Access: Indexing. Each slot is accessed through a remote
HOST #.
* Specific feature: Throughout the whole table no more
than 64 bits can be turned on. This
figure corresponds to the maximum
number of outgoing links that can be
activated at one time (No matter what
is the number of remote HOST[s]).
(b) CONNECT table
This table keeps track of all the connections' environment.
It has the following characteristics:
* Location: Disc resident
* Coupling: Couples to the Network process virtual space
* Size: As many slots as connections in use.
* Slot structure: See figure 6. Each slot is 2 word
length
* Access: Indexing. Each slot is accessed through a
connection #. See 3.4 the way it is handled.
* Specific feature 1: The slot structure corresponding to
a primary connection is not
identical to that of an auxiliary
connection (See figure 7). This
because user identifications and
requests are done through primary
shared pages.
* Specific feature 2: This table is handled in parallel
with the connection pages (See 3.3.2
(b))
Deloche [Page 14]
RFC 11 Host - Host Software Procedures in GORDO August 1969
* Specific feature 3: This table is mainly used for
transmitting messages. (For each
connection it contains the outgoing
link # and remote HOST #, i.e., all
the information required for
transmitting a message.)
(c) INPUT LINK table
This table keeps track of all the incoming (input) links and
so is closely related to the CONNECT table.
[Figure 5 - HOST table - see PDF file]
[Figure 6 - CONNECT table: Slot structure - see PDF file]
[Figure 7 - INSERT LINK table: Slot structure - see PDF file]
It has the following characteristics:
* Location: Disc resident.
* Coupling: Coupled to the Network process virtual space.
* Size: As many slots as incoming links, i.e., as
connections
* Slot structure: See figure 7. Each slot is 1 word
length
* Access: Hashing. The hashed key value is mainly based
upon the incoming link # and the remote HOST #.
* Specific feature 1: This table is also used for
momentarily memorizing the
connection number while establishing
the next connection. See 3.4 the
way it is handled.
* Specific feature 2: This table is primarily used upon
receiving messages. (For each
incoming link it contains the
corresponding connection #, i.e.,
indirectly the user identification
to which the message should be
passed along)
Deloche [Page 15]
RFC 11 Host - Host Software Procedures in GORDO August 1969
3.3.1.2 Buffer pages
All the pages that are now to be described contain two buffers
(input and output). These buffers are used for either passing
along or processing messages.
The size of each of these buffers should at least be equal to that
of a message, i.e., 8095 bits. We have chosen a buffer size of
253 words (8096 bits) so that both of the buffers are included
within one page (512 words). The 6 remaining words of the page
are generally used for control.
A typical buffer page structure is identified on figure 8.
(a) I/O communication page
See figure 9.
This I/O communication page is used as an interface between the
Handler and the Network program.
In the buffers of this page the messages are assembled (input)
or de-assembled (output) word by word by the Handler, e.g., a
"ready to go" message, sorted by the Network program in the
output buffer, is shipped out word by word by the Handler.
Main characteristics:
* Location: Resident in core: Locked page
* Coupling: Coupled to the Network process virtual space
* Content: * Input buffer (253 words) for incoming messages
Output buffer (253 words) for outgoing messages
* Input control zone (6 half words)
* Output control zone (6 half words)
* Structure: See figure 9.
* Specific feature: * The input buffer is filled by the
Handler (read from hardware) and emptied
by the Network program
* Vice versa for the output buffer
(b) Connection shared pages (User-Network shared zone)
General features:
* There are as many shared pages as connections.
* These pages shared between the network and the user
processes constitute a communication zone for (1) passing
Deloche [Page 16]
RFC 11 Host - Host Software Procedures in GORDO August 1969
the messages back and forth, and (2) exchanging control
information, e.g., a request for establishing new
connections.
Main characteristics:
* Location: Disc resident
* Coupling: Coupled to both a user process virtual space and
the
network process virtual space.
* Content: - Input buffer (253 words) for incoming messages
- Output buffer (253 words) for outgoing messages
- Input control zone (6 half words)
- Output control zone (6 half words)
* Structure: See figure 10.
* Specific feature 1: - The input buffer is filled by the
Network and emptied by the user.
- Vice versa for the output buffer.
* Specific feature 2: The control zone corresponding to a
primary connection shared page differs
from that of an auxiliary connection.
This because it is via a "primary
connection control zone" that
auxiliary connection establishment
requests are transmitted to the
Network process.
(c) Working page
General feature:
* This page allows the Network and the Handler programs to
work independently on different messages and so contributes to
an overlapping. For instance, when the Handler is busy
transmitting a message to the hardware, the Network program can
format (leader, marking, etc.) the reset message to be shipped
out, so that it can reinitiate the Handler as soon as it is
free.
Main characteristics:
* Location: Disc resident
* Coupling: Coupled to the Network process virtual space
* Content: - Input buffer (253 words) for incoming messages
- Output buffer (253 words) for outgoing messages
Deloche [Page 17]
RFC 11 Host - Host Software Procedures in GORDO August 1969
Remark:
During reception it may happen that a user program is not ready
to accept a new message. In that case, to avoid clogging up
the system, the Network stores momentarily the incoming message
in one of the buffer of the emergency ring. (If this ring is
full a help routine will be invoked.)
During emission all operations are synchronized with the
RFNM[s], therefore such procedures need not be provided. (The
Network program allows a user to re-emit only when having
received the RFNM of the previous transmitted message.)
[Figure 8 - Typical buffer page - see PDF file]
[Figure 9 - I/O Communication page structure - see PDF file]
[Figure 10 - Connection shared page structure - see PDF file]
3.3.2 Programs
3.3.2.1 Handler program
General features:
It is an I/O interrupt routine which drives the IMP/HOST hardware
interface in order to transmit or receive messages. Transmission
and reception are carried out in a full duplex mode.
Main characteristics:
* Location: Core resident. The Handler is in the same memory
zone as the operating system and can be considered
as part of it.
* Initiation: By the IMP-HOST hardware interrupt. This interrupt
is triggered either:
* during transmission when a message word is
completely sent to the IMP
* during reception when a message word has been
completely received from the IMP
* during idle time when the hardware received
either a 'start input' or 'start output' order
from the Sigma 7 CPU. Those orders are issued by
the Network program for provoking interrupts back
Deloche [Page 18]
RFC 11 Host - Host Software Procedures in GORDO August 1969
(consequently for indirectly initiating the
Handler).
* Main functions: * Empties the output buffer upon transmitting
its content (outgoing message to the IMP.
This operation is carried out word by word
(32 bits) and makes use of "Write" orders for
driving the HOST-IMP hardware.
* Fills the input buffer with data received
from HOST-IMP hardware (incoming message).
This operation is also carried out word by
word and makes use of "Read" orders for
driving the HOST-IMP hardware.
* Wakes up the Network program when any of the
previous operations is complete.
3.3.2.2 Network program
General features:
This program serves the user for opening/closing connections and
transmitting/receiving messages. It uses the Handler as an aid
for inter-facing with the hardware.
For the GORDO point of view it is a regular process and treated as
such.
Main characteristics:
* Location: Disc resident. More precisely it is on disc when
asleep and called in core when awakened by a
program.
* Initiation: It is initiated through 'WAKE' service calls
issued either by a user process or by the Handler.
* Main functions: * Establishes/deletes outgoing connections upon
users' requests. For so doing it sends
control messages (see 2.4.2) to remote
HOST[s] in order to get links
established/released; it then notifies back
the users.
* Insures the processing of incoming control
messages (transmitted over control links),
e.g., for contributing to
establishments/deletions of connections
(those requested by remote HOSTS).
Deloche [Page 19]
RFC 11 Host - Host Software Procedures in GORDO August 1969
* Prepares transmission of outgoing messages.
It picks up text messages from shared pages
(the messages are stored there by users),
formats them (adds leader, marking,
checksum..), and passes them along to the
Handler for transmission.
* Insures delivery of incoming messages. It is
the opposite of the above operation. The
users to which the messages should be
delivered are identified through the leaders.
* Virtual space configuration: See figure 11.
* Specific feature: It is integrated as an I/O process, so that
it can access privileged instruction (RD/WD
for indirectly initiating the Handler).
[Figure 11 - Network Process Virtual Space - see PDF file]
3.4 Software Procedures
The detailed software procedures are given on the flowcharts attached
with Appendix A.
However, to get a quick understanding of the implementation we list
below some typical software procedures.
3.4.1 Description of some typical sequences
Consider some of the transactions at user's disposal (See 2.4) and
point out the basic software procedures they imply. For each case we
will delineate (i) what the user program does and (ii) what the
Network program does.
(a) Open a primary link (See also 2.4.2)
(i) What the user program does[1]:
* it stores in the Network mail box directory the name of
a file, e.g., DATA;
* it couples the first page of this file to its virtual
space;
* it stores information in this page (its job/process #,
the remote HOST #, e.g., (i));
* it wakes up the Network process;
* it goes to sleep.
Deloche [Page 20]
RFC 11 Host - Host Software Procedures in GORDO August 1969
(ii) What the Network program does:
* it explores the Network mail box directory and accesses
the file DATA;
* it couples the first page of this file to its virtual
space (Shared Zone, see 3.3.1.2). Suppose this page to
be kth in the shared zone; k is the internal connection
#;
* it explores the ith slot of the new HOST table (See
3.3.1.1 (a)) and selects the first bit = 0, e.g., the
(alpha)th bit; alpha corresponds to the outgoing link
#;
* it stores information (job/process #, remote HOST #
(i), outgoing link # (alpha)) in the kth slot of the
CONNECT table (See 3.3.1.2).
* it momentarily stores the connection # (k) in the INPUT
LINK table. This is carried out upon creating an entry
in this table (Hashing the key value: "outgoing link #
(alpha) + remote HOST # (i) + outgoing flag".);
* it prepares the message text ENQ PRIM 0 0 a and formats
a complete message in adding leader, marking, checksum,
etc.;
* it checks the Handler state (bit in I/O locked page).
If the Handler is free, it stores the 'ready to go'
control message in the output buffer of the I/O locked
page, initiates the Handler, and goes to sleep. Else
it goes to sleep.
After a while the Handler wakes up the Network process because it has
received a complete message. We suppose this message be the control
message sent by the remote HOST for acknowledging the establishment
of the connection. The message text should be:
ACK ENQ PRIM 0 0 alpha 0 0 beta
where beta is the incoming link #. (See 2.4.2)
Let's see now what the Network program does when receiving the above
control message:
* it retrieves the connection # previously stored in the
INPUT LINK table upon re-hashing the same key value
(See above). Also it deletes this entry;
* it creates an entry in the INPUT LINK table for the
incoming link. For so doing it hashes the key value:
"incoming link # (beta]) + remote HOST # (i) +
"incoming flag". In this entry it stores the HOST #
(i), the incoming link # (beta), and connection # (k);
Deloche [Page 21]
RFC 11 Host - Host Software Procedures in GORDO August 1969
* it updates the kth slot of the CONNECT table in storing
the incoming link # (beta);
* it turns on the 'net-user' bit in the kth shared page
(page corresponding to the primary connection that has
just been opened) and wakes up the user process;
* it goes to sleep.
(b) Transmit a message over primary link
(i) What the user program does[1].
* it stores the message text in the output buffer of the
primary connection shared page (see 3.3.1.2);
* it turns on the 'user-net' bit of this page and wakes
up the Network process;
* it goes to sleep.
(ii) What the Network program does:
* it looks for user request, i.e., it explores in
sequence the connection shared pages and selects the
one that has its 'user-net' bit turned on. Suppose k
be the selected page # on the shared list, K is the
connection #;
* it determines the request type in testing the 'request
bits' of the shared page k. It finds out that it is a
request for transmitting a message.
* it takes the message text from the output buffer of the
shared page k, formats it into a complete message and
transmits to the Handler in a very similar way as above
(See Open a primary link).
* it goes to sleep.
[1] Remark: In a first phase the user will directly write the
network functions in his program. Later on
subroutines will be put at user's disposal. These
subroutines will be very close to those described in
2.4.
Deloche [Page 22]
RFC 11 Host - Host Software Procedures in GORDO August 1969
APPENDIX A
Flowcharts
[see PDF file for flowcharts]
[ This RFC was put into machine readable form for entry ]
[ into the online RFC archives by Bob German 8/99 ]
Deloche [Page 23]
Html markup produced by rfcmarkup 1.129b, available from