RFC 1407 Definitions of Managed Objects for the DS3/E3 Interface Type

[Docs] [txt|pdf] [draft-ietf-trun...] [Tracker] [Diff1] [Diff2]

Obsoleted by: 2496 PROPOSED STANDARD

Network Working Group                                             T. Cox
Request for Comments: 1407                                     K. Tesink
Obsoletes: 1233                             Bell Communications Research
                                                                 Editors
                                                            January 1993


                     Definitions of Managed Objects
                     for the DS3/E3 Interface Type

Status of this Memo

   This RFC specifies an IAB standards track protocol for the Internet
   community, and requests discussion and suggestions for improvements.
   Please refer to the current edition of the "IAB Official Protocol
   Standards" for the standardization state and status of this protocol.
   Distribution of this memo is unlimited.

Abstract

   This memo defines an extension to the Management Information Base
   (MIB) for use with network management protocols in TCP/IP-based
   internets.  In particular, it defines objects for managing DS3 and E3
   Interfaces.  This document is a companion document with Definitions
   of Managed Objects for the DS1 Interface Type.

   This document entirely replaces RFC 1233, which contains a
   fundamental error: many objects are encoded as Counters that must be
   encoded as INTEGERs or Gauges.  The magnitude of the change required
   is sufficient that virtually every object changed.  Therefore, the
   MIB documented in RFC 1233 should not be implemented.

Table of Contents

   1. The Network Management Framework ......................    2
   2. Objects ...............................................    2
   2.1 Format of Definitions ................................    3
   2.2 Changes from RFC 1233 ................................    3
   3. Overview ..............................................    5
   3.1 Binding between ifIndex and DS3/E3 Interfaces ........    5
   3.2 Objectives of this MIB Module ........................    7
   3.3 DS3/E3 Terminology ...................................    7
   3.3.1 Error Events .......................................    7
   3.3.2 Performance Parameters .............................    8
   3.3.3 Performance Defects ................................   10
   3.3.4 Other Terms ........................................   11
   4. Object Definitions ....................................   12
   4.1 The DS3/E3 Near End Group ............................   12



Trunk MIB Working Group                                         [Page 1]


RFC 1407                       DS3/E3 MIB                   January 1993


   4.1.1 The DS3/E3 Configuration ...........................   12
   4.1.2 The DS3/E3 Current .................................   18
   4.1.3 The DS3/E3 Interval ................................   21
   4.1.4 The DS3/E3 Total ...................................   25
   4.2 The DS3 Far End Group ................................   29
   4.2.1 The DS3 Far End Configuration ......................   29
   4.2.2 The DS3 Far End Current ............................   31
   4.2.3 The DS3 Far End Interval ...........................   34
   4.2.4 The DS3 Far End Total ..............................   36
   4.3 The DS3/E3 Fractional Group ..........................   38
   5. Acknowledgments .......................................   41
   6. References ............................................   41
   7. Security Considerations ...............................   43
   8. Authors' Addresses ....................................   43

1.  The Network Management Framework

   The Internet-standard Network Management Framework consists of three
   components.  They are:

      STD 16/RFC 1155 which defines the SMI, the mechanisms used for
      describing and naming objects for the purpose of management.  STD
      16/RFC 1212 defines a more concise description mechanism, which is
      wholly consistent with the SMI.

      RFC 1156 which defines MIB-I, the core set of managed objects for
      the Internet suite of protocols.  STD 17/RFC 1213, defines MIB-II,
      an evolution of MIB-I based on implementation experience and new
      operational requirements.

      STD 15/RFC 1157 which defines the SNMP, the protocol used for
      network access to managed objects.

   The Framework permits new objects to be defined for the purpose of
   experimentation and evaluation.

2.  Objects

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  Objects in the MIB are
   defined using the subset of Abstract Syntax Notation One (ASN.1) [7]
   defined in the SMI.  In particular, each object has a name, a syntax,
   and an encoding.  The name is an object identifier, an
   administratively assigned name, which specifies an object type.  The
   object type together with an object instance serves to uniquely
   identify a specific instantiation of the object.  For human
   convenience, we often use a textual string, termed the OBJECT
   DESCRIPTOR, to also refer to the object type.



Trunk MIB Working Group                                         [Page 2]


RFC 1407                       DS3/E3 MIB                   January 1993


   The syntax of an object type defines the abstract data structure
   corresponding to that object type.  The ASN.1 language is used for
   this purpose.  However, the SMI [3] purposely restricts the ASN.1
   constructs which may be used.  These restrictions are explicitly made
   for simplicity.

   The encoding of an object type is simply how that object type is
   represented using the object type's syntax.  Implicitly tied to the
   notion of an object type's syntax and encoding is how the object type
   is represented when being transmitted on the network.  The SMI
   specifies the use of the basic encoding rules of ASN.1 [8], subject
   to the additional requirements imposed by the SNMP.

2.1.  Format of Definitions

   Section 4 contains contains the specification of all object types
   contained in this MIB module.  The object types are defined using the
   conventions defined in the SMI, as amended by the extensions
   specified in STD 16, RFC 1212 [13].

2.2.  Changes from RFC 1233

   This MIB obsoletes RFC 1233.  The changes from RFC 1233 are the
   following:

      --  This MIB module contains information to manage
          an E3 interface, also.

      --  This MIB module contains three groups:
           DS3/E3 Near End Group which is mandatory,
           DS3 Far End Group which is optional, and
           DS3 Fractional Group which is optional.

      --  The DS3 Far End Group is a new group and contains
          configuration information and statistics
          that are collected from the far end DS3/E3 interface.
          Presently, the Far End Group may only be implemented by
          DS3 systems that use C-bit Parity or SYNTRAN.

      --  The DS3 Fractional Group is a new group and is
          modeled after the DS1 Fractional Group.

      --  ds3CSUIndex has been redefined and renamed
          to dsx3LineIndex.  This object
          is the identifier of a DS3/E3 Interface on a device.
          On a CSU, a single DS3/E3 data stream will cross two DS3/E3
          interfaces, which have separate dsx3LineIndex values.




Trunk MIB Working Group                                         [Page 3]


RFC 1407                       DS3/E3 MIB                   January 1993


      --  ds3Index has been redefined and renamed to
          dsx3IfIndex.  This value for this
          object is equal to the value of ifIndex from the Interfaces
          table of MIB II (STD 17, RFC 1213).

      --  The ACCESS for objects in the dsx3ConfigTable has
          been set to read-write for items that are configurable.

      --  The dsx3ZeroCoding has been renamed to dsx3LineCoding.

      --  A new object has been added called dsx3LoopbackConfig,
          which better describes the loopback capabilities of
          a DS3/E3 interface on a device.

      --  The dsx3SendCode object has been updated to reflect
          different types of loopback messages.

      --  A new object has been added called dsx3LineStatus.
          This object better describes the status (e.g.,
          failure state and loopback state) of a
          DS3/E3 interface.

      --  A new object has been added called dsx3TransmitClockSource.
          This object identifies the source for the transmit clock.

      --  All Counters have been changed to Gauges.

      --  A Line Errored Seconds object has been added to
          all near end tables.

      --  Line Coding Violations are counted instead of Bipolar
          Violations.

      --  A new Coding Violation counter has been added to count
          coding violations reported via the C-bits of SYNTRAN
          and C-bit Parity DS3 applications.
          The original Coding Violation counter has been renamed
          to PCV to mean coding violations reported via the P-bits.
          This count is also added for symmetry with the far end
          statistics.

      --  A new Errored Second counter and Severely Errored Second
          counter has been added to count these performance events
          via the C-bits of the SYNTRAN and C-bit Parity DS3
          applications.  The original ES and SES counters have been
          renamed to PES and PSES to mean reported via the P-bits.
          These counts are also added for symmetry with the far end
          statistics.



Trunk MIB Working Group                                         [Page 4]


RFC 1407                       DS3/E3 MIB                   January 1993


3.  Overview

   These objects are used when the particular media being used to
   realize an interface is a DS3/E3 interface.  At present, this applies
   to these values of the ifType variable in the Internet-standard MIB:

               ds3 (30)

   The DS3 definitions contained herein are based on the DS3
   specifications in ANSI T1.102-1987, ANSI T1.107-1988, ANSI T1.107a-
   1990, and ANSI T1.404-1989 [9,10,10a,11].  The E3 definitions
   contained herein are based on the E3 specifications in CCITT G.751
   [14].

3.1.  Binding between ifIndex and DS3/E3 Interfaces

   Different physical configurations for the support of SNMP with DS3/E3
   equipment exist. To accommodate these scenarios, two different
   indices for DS3/E3 interfaces are introduced in this MIB.  These
   indices are dsx3IfIndex and dsx3LineIndex.

   External interface scenario: the SNMP Agent represents all managed
   DS3/E3 lines as external interfaces (for example, an Agent residing
   on the device supporting DS3/E3 interfaces directly):

   For this scenario, all interfaces are assigned an integer value equal
   to ifIndex, and the following applies:

             ifIndex=dsx3IfIndex=dsx3LineIndex for all interfaces.

   The dsx3IfIndex column of the DS3/E3 Configuration table relates each
   DS3/E3 interface to its corresponding interface (ifIndex) in the
   Internet-standard MIB (MIB-II STD 17, RFC 1213).

   External&Internal interface scenario: the SNMP Agents resides on an
   host external from the device supporting DS3/E3 interfaces (e.g., a
   router). The Agent represents both the host and the DS3/E3 device.
   The index dsx3LineIndex is used to not only represent the DS3/E3
   interfaces external from the host/DS3/E3-device combination, but also
   the DS3/E3 interfaces connecting the host and the DS3/E3 device.  The
   index dsx3IfIndex is always equal to ifIndex.

   Example:

   A shelf full of CSUs connected to a Router. An SNMP Agent residing on
   the router proxies for itself and the CSU. The router has also an
   Ethernet interface:




Trunk MIB Working Group                                         [Page 5]


RFC 1407                       DS3/E3 MIB                   January 1993


          +-----+
    |     |     |
    |     |     |               +---------------------+
    |E    |     |  44.736 MBPS  |   ds3 M13    Line#A | ds3 C-bit Parity
    |t    |  R  |---------------+ - - - - -  - - -  - +------>
    |h    |     |               |                     |
    |e    |  O  |  44.736 MBPS  |   ds3 M13    Line#B | ds3 C-bit Parity
    |r    |     |---------------+ - - - - - - - - - - +------>
    |n    |  U  |               |                     |
    |e    |     |  44.736 MBPS  |   ds3 M13    Line#C | ds3 C-bit Parity
    |t    |  T  |---------------+ - - - -- -- - - - - +------>
    |     |     |               |                     |
    |-----|  E  |  44.736 MBPS  |   ds3 M13    Line#D | ds3 C-bit Parity
    |     |     |---------------+ -  - - - -- - - - - +------>
    |     |  R  |               |_____________________|
    |     |     |
    |     +-----+

   The assignment of the index values could for example be:

            ifIndex (= dsx3IfIndex)                     dsx3LineIndex

                    1                   NA                  NA (Ethernet)
                    2      Line#A   Router Side             6
                    2      Line#A   Network Side            7
                    3      Line#B   Router Side             8
                    3      Line#B   Network Side            9
                    4      Line#C   Router Side            10
                    4      Line#C   Network Side           11
                    5      Line#D   Router Side            12
                    5      Line#D   Network Side           13

   For this example, ifNumber is equal to 5.  Note the following
   description of dsx3LineIndex: the dsx3LineIndex identifies a DS3/E3
   Interface on a managed device.  If there is an ifEntry that is
   directly associated with this and only this DS3/E3 interface, it
   should have the same value as ifIndex.  Otherwise, number the
   dsx3LineIndices with an unique identifier following the rules of
   choosing a number greater than ifNumber and numbering inside
   interfaces (e.g., equipment side) with even numbers and outside
   interfaces (e.g., network side) with odd numbers.

   If the CSU shelf is managed by itself by a local SNMP Agent, the
   situation would be:







Trunk MIB Working Group                                         [Page 6]


RFC 1407                       DS3/E3 MIB                   January 1993


            ifIndex (= dsx3IfIndex)                      dsx3LineIndex

                    1      Line#A     Network Side            1
                    2      Line#A     RouterSide              2
                    3      Line#B     Network Side            3
                    4      Line#B     RouterSide              4
                    5      Line#C     Network Side            5
                    6      Line#C     Router Side             6
                    7      Line#D     Network Side            7
                    8      Line#D     Router Side             8

3.2.  Objectives of this MIB Module

   There are numerous things that could be included in a MIB for DS3/E3
   signals: the management of multiplexors, CSUs, DSUs, and the like.
   The intent of this document is to facilitate the common management of
   all devices with DS3/E3 interfaces.  As such, a design decision was
   made up front to very closely align the MIB with the set of objects
   that can generally be read from DS3/E3 devices that are currently
   deployed.

3.3.  DS3/E3 Terminology

   The terminology used in this document to describe error conditions on
   a DS3 interface as monitored by a DS3 device are based on the
   definitions from the ANSI T1M1.3/92-005R1 draft standard [12].  If
   the definition in this document does not match the definition in the
   ANSI T1M1.3/92-005R1 draft document, the implementer should follow
   the definition described in this document.

3.3.1.  Error Events

          Bipolar Violation (BPV) Error Event
            A bipolar violation error event, for B3ZS(HDB3)-coded
            signals, is the occurrence of a pulse of the same polarity
            as the previous pulse without being part of the zero
            substitution code, B3ZS(HDB3).  For B3ZS(HDB3)-coded
            signals, a bipolar violation error event may also include
            other error patterns such as:  three(four) or more
            consecutive zeros and incorrect polarity.

          Excessive Zeros (EXZ) Error Event
            An EXZ is the occurrence of any zero string length equal
            to or greater than 3 for B3ZS, or greater than 4 for HDB3.

          Line Coding Violation (LCV) Error Event
            This parameter is a count of both BPVs and EXZs
            occurring over the accumulation period.  An EXZ



Trunk MIB Working Group                                         [Page 7]


RFC 1407                       DS3/E3 MIB                   January 1993


            increments the LCV by one regardless of the length
            of the zero string.

          P-bit Coding Violation (PCV) Error Event
            For all DS3 applications, a coding violation error
            event is a P-bit
            Parity Error event.  A P-bit Parity Error event is the
            occurrence of a received P-bit code on the DS3 M-frame
            that is not identical to the corresponding locally-
            calculated code.

          C-bit Coding Violation (CCV) Error Event
            For C-bit Parity and SYNTRAN DS3 applications, this is
            the count of coding violations reported via the C-bits.
            For C-bit Parity, it is a count of CP-bit parity errors
            occurring in the accumulation interval.  For SYNTRAN, it
            is a count of CRC-9 errors occurring in the accumulation
            interval.

3.3.2.  Performance Parameters

   All performance parameters are accumulated in fifteen minute
   intervals and up to 96 intervals (24 hours worth) are kept by an
   agent.  Fewer than 96 intervals of data will be available if the
   agent has been restarted within the last 24 hours.  In addition,
   there is a rolling 24-hour total of each performance parameter.

   There is no requirement for an agent to ensure fixed relationship
   between the start of a fifteen minute interval and any wall clock;
   however some agents may align the fifteen minute intervals with
   quarter hours.

          Line Errored Seconds (LES)
            A Line Errored Second is a second in
            which one or more CVs occurred OR one or more LOS defects.

          P-bit Errored Seconds (PES)
            An PES is a second with one or more PCVs OR
            one or more Out of Frame defects OR a detected incoming AIS.
            This gauge is not incremented when UASs are counted.

          P-bit Severely Errored Seconds (PSES)
            A PSES is a second with 44 or more PCVs OR
            one or more Out of Frame defects OR a detected incoming AIS.
            This gauge is not incremented when UASs are counted.

          C-bit Errored Seconds (CES)
            An CES is a second with one or more CCVs OR



Trunk MIB Working Group                                         [Page 8]


RFC 1407                       DS3/E3 MIB                   January 1993


            one or more Out of Frame defects OR a detected incoming AIS.
            This count is only for the SYNTRAN and C-bit Parity DS3
            applications.  This gauge is not incremented when UASs are
            counted.

          C-bit Severely Errored Seconds (CSES)
            A CSES is a second with 44 or more CCVs OR
            one or more Out of Frame defects OR a detected incoming AIS.
            This count is only for the SYNTRAN and C-bit Parity DS3
            applications.  This gauge is not incremented when UASs
            are counted.

          Severely Errored Framing Seconds (SEFS)
            A SEFS is a second with one or more Out of Frame defects
            OR a detected incoming AIS.

          Unavailable Seconds (UAS)
            UAS are calculated by counting the number of seconds that
            the interface is unavailable.  The DS3 interface is said
            to be unavailable from the onset of 10 contiguous PSESs, or
            the onset of the condition leading to a failure (see Failure
            States).  If the condition leading to the failure was
            immediately preceded by one or more contiguous PSESs, then
            the DS3 interface unavailability starts from the onset of
            these PSESs.  Once unavailable, and if no failure is
            present, the DS3 interface becomes available at the onset
            of 10 contiguous seconds with no PSESs.  Once unavailable,
            and if a failure is present, the DS3 interface becomes
            available at the onset of 10 contiguous seconds with no
            PSESs, if the failure clearing time is less than
            or equal to 10 seconds.  If the failure clearing time is
            more than 10 seconds, the DS3 interface becomes available
            at the onset of 10 contiguous seconds with no PSESs, or
            the onset period leading to the successful clearing
            condition, whichever occurs later.  With respect to the
            DS3 error counts, all counters are incremented
            while the DS3 interface is deemed available.  While the
            interface is deemed unavailable, the only count that is
            incremented is UASs.

            A special case exists when the 10 or more second period
            crosses the 900 second statistics window boundary, as the
            foregoing description implies that the PSES and UAS
            counters must be adjusted when the Unavailable Signal
            State is entered. Clearly, successive GETs of the
            affected dsx3IntervalPSESs and dsx3IntervalUASs objects
            will return differing values if the first GET occurs
            during the first few seconds of the window.  This is



Trunk MIB Working Group                                         [Page 9]


RFC 1407                       DS3/E3 MIB                   January 1993


            viewed as an unavoidable side-effect of selecting the
            presently defined managed objects as a basis for this
            memo.

3.3.3.  Performance Defects

          Failure States:
            The Remote Alarm Indication (RAI) failure, in SYNTRAN
            applications, is declared after detecting
            the Yellow Alarm Signal on the alarm channel.  See ANSI
            T1.107a-1990 [10].  The Remote Alarm Indication failure,
            in C-bit Parity DS3 applications, is declared
            as soon as the preqsence of either one or two alarm signals
            are detected on then Far End Alarm Channel.  See [10].
            The Remote Alarm Indication failure may also be declared
            after detecting the far-end SEF/AIS defect (aka yellow).
            The Remote Alarm Indication failure is cleared as soon as
            the presence of the any of the above alarms are removed.

            Also, the incoming failure state is declared when a defect
            persists for at least 2-10 seconds.  The defects are
            the following:  Loss of Signal (LOS), an Out of Frame (OOF)
            or an incoming Alarm Indication Signal (AIS).
            The Failure State is cleared when the defect is absent
            for less than or equal to 20 seconds.

          Far End SEF/AIS defect (aka yellow)
            A Far End SEF/AIS defect is the occurrence of the two X-bits
            in a M-frame set to zero.  The Far End SEF/AIS defect is
            terminated when the two X-bits in a M-frame are set to
            one.

          Out of Frame (OOF) defect
            A DS3 OOF defect is detected when any three or more errors
            in sixteen or fewer consecutive F-bits occur within a DS3
            M-frame.  An OOF defect may also be called a Severely
            Errored Frame (SEF) defect.  An OOF defect is cleared when
            reframe occurs.  A DS3 Loss of Frame (LOF) failure is
            declared when the DS3 OOF defect is consistent for 2 to 10
            seconds.  The DS3 OOF defect ends when reframe occurs.
            The DS3 LOF failure is cleared when the DS3 OOF
            defect is absent for 10 to 20 seconds.

            An E3 OOF defect is detected when four consecutive frame
            alignment signals have been incorrectly received in there
            predicted positions in an E3 signal. E3 frame alignment
            occurs when the presence of three consecutive frame
            alignment signals have been detected.



Trunk MIB Working Group                                        [Page 10]


RFC 1407                       DS3/E3 MIB                   January 1993


          Loss of Signal (LOS) defect
            The DS3 LOS defect is declared upon observing 175 +/- 75
            contiguous pulse positions with no pulses of either
            positive or negative polarity.
            The DS3 LOS defect is terminated upon observing an average
            pulse density of at least 33% over a period of 175 +/- 75
            contiguous pulse positions starting with the receipt of a
            pulse.

          Alarm Indication Signal (AIS) defect
            The DS3 AIS is framed with "stuck stuffing."  This implies
            that it has a valid M-subframe alignments bits, M-frame
            alignment bits, and P bits.  The information bits are set
            to a 1010... sequence, starting with a one (1) after each
            M-subframe alignment bit, M-frame alignment bit, X bit, P
            bit, and C bit.  The C bits are all set to zero giving
            what is called "stuck stuffing."  The X bits are set to
            one.  The DS3 AIS defect is declared after DS3 AIS is
            present in contiguous M-frames for a time equal to or
            greater than T, where 0.2 ms <= T <= 100 ms.
            The DS3 AIS defect is terminated after AIS is absent in
            contiguous M-frames for a time equal to or greater than T.

            The E3 binary content of the AIS is nominally a continuous
            stream of ones.  AIS detection and the application of
            consequent actions, should be completed within a time
            limit of 1 ms.

3.3.4.  Other Terms

          Circuit Identifier
            This is a character string specified by the circuit
            vendor, and is useful when communicating with the vendor
            during the troubleshooting process.

















Trunk MIB Working Group                                        [Page 11]


RFC 1407                       DS3/E3 MIB                   January 1993


4.  Object Definitions

               RFC1407-MIB DEFINITIONS ::= BEGIN

               IMPORTS
                       Gauge
                               FROM RFC1155-SMI
                       DisplayString, transmission
                               FROM RFC1213-MIB
                       OBJECT-TYPE
                               FROM RFC-1212;

               -- This MIB module uses the extended OBJECT-TYPE macro
               -- as defined in RFC 1212.

                       ds3  OBJECT IDENTIFIER ::= { transmission 30 }


               -- The DS3/E3 Near End Group

               -- Implementation of this group is mandatory for all
               -- systems that attach to a DS3/E3 Interface.

               -- The DS3/E3 Near End Group consists of four tables:
               --    DS3/E3 Configuration
               --    DS3/E3 Current
               --    DS3/E3 Interval
               --    DS3/E3 Total

               -- the DS3/E3 Configuration

               dsx3ConfigTable OBJECT-TYPE
                   SYNTAX  SEQUENCE OF Dsx3ConfigEntry
                   ACCESS  not-accessible
                   STATUS  mandatory
                   DESCRIPTION
                           "The DS3/E3 Configuration table."
                  ::= { ds3 5 }

              dsx3ConfigEntry OBJECT-TYPE
                  SYNTAX  Dsx3ConfigEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "An entry in the DS3/E3 Configuration table."
                 INDEX   { dsx3LineIndex }
                 ::= { dsx3ConfigTable 1 }




Trunk MIB Working Group                                        [Page 12]


RFC 1407                       DS3/E3 MIB                   January 1993


             Dsx3ConfigEntry ::=
                 SEQUENCE {
                     dsx3LineIndex
                         INTEGER,
                     dsx3IfIndex
                         INTEGER,
                     dsx3TimeElapsed
                         INTEGER,
                     dsx3ValidIntervals
                         INTEGER,
                     dsx3LineType
                         INTEGER,
                     dsx3LineCoding
                         INTEGER,
                     dsx3SendCode
                         INTEGER,
                     dsx3CircuitIdentifier
                         DisplayString,
                     dsx3LoopbackConfig
                         INTEGER,
                     dsx3LineStatus
                         INTEGER,
                     dsx3TransmitClockSource
                         INTEGER
             }

             dsx3LineIndex OBJECT-TYPE
                 SYNTAX  INTEGER (1..65535)
                 ACCESS  read-only
                 STATUS  mandatory
                 DESCRIPTION
                         "This object is the identifier of a DS3/E3
                         Interface on a managed device.  If there is an
                         ifEntry that is directly associated with this
                         and only this DS3/E3 interface, it should have
                         the same value as ifIndex.  Otherwise, number
                         the dsx3LineIndices with an unique identifier
                         following the rules of choosing a number that
                         is greater than ifNumber and numbering the
                         inside interfaces (e.g., equipment side) with
                         even numbers and outside interfaces (e.g,
                         network side) with odd numbers."
                ::= { dsx3ConfigEntry 1 }

            dsx3IfIndex OBJECT-TYPE
                SYNTAX  INTEGER (1..65535)
                ACCESS  read-only
                STATUS  mandatory



Trunk MIB Working Group                                        [Page 13]


RFC 1407                       DS3/E3 MIB                   January 1993


                DESCRIPTION
                        "This value for this object is equal to the
                        value of ifIndex from the Interfaces table of
                        MIB II (RFC 1213)."
               ::= { dsx3ConfigEntry 2 }

           dsx3TimeElapsed OBJECT-TYPE
               SYNTAX  INTEGER (0..899)
               ACCESS  read-only
               STATUS  mandatory
               DESCRIPTION
                       "The number of seconds that have elapsed since
                       the beginning of the near end current error-
                       measurement period."
              ::= { dsx3ConfigEntry 3 }

          dsx3ValidIntervals OBJECT-TYPE
              SYNTAX  INTEGER (0..96)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of previous near end intervals for
                      which valid data was collected.  The value will be
                      96 unless the interface was brought online within
                      the last 24 hours, in which case the value will be
                      the number of complete 15 minute near end
                      intervals since the interface has been online."
              ::= { dsx3ConfigEntry 4 }

          dsx3LineType OBJECT-TYPE
              SYNTAX  INTEGER {
                          dsx3other(1),
                          dsx3M23(2),
                          dsx3SYNTRAN(3),
                          dsx3CbitParity(4),
                          dsx3ClearChannel(5),
                          e3other(6),
                          e3Framed(7),
                          e3Plcp(8)
                      }
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "This variable indicates the variety of DS3 C-bit
                      or E3 application
                      implementing this interface.  The type of
                      interface affects the interpretation of the
                      usage and error statistics.



Trunk MIB Working Group                                        [Page 14]


RFC 1407                       DS3/E3 MIB                   January 1993


                      The rate of DS3 is 44.736 Mbps and E3 is
                      34.368 Mbps.
                      The dsx3ClearChannel value means that the C-bits
                      are not used except for sending/receiving
                      AIS.

                      The values, in sequence, describe:

                      TITLE:            SPECIFICATION:
                      dsx3M23            ANSI T1.107-1988
                      dsx3SYNTRAN        ANSI T1.107-1988
                      dsx3CbitParity     ANSI T1.107a-1989
                      dsx3ClearChannel   ANSI T1.102-1987
                      e3Framed           CCITT G.751
                      e3Plcp             ETSI T/NA(91)18."
              ::= { dsx3ConfigEntry 5 }

          dsx3LineCoding OBJECT-TYPE
              SYNTAX  INTEGER {
                          dsx3Other(1),
                          dsx3B3ZS(2),
                          e3HDB3(3)
                      }
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "This variable describes the variety of Zero Code
                      Suppression used on this interface, which in turn
                      affects a number of its characteristics.

                      dsx3B3ZS and e3HDB3 refer to the use of specified
                      patterns of normal bits and bipolar violations
                      which are used to replace sequences of zero bits
                      of a specified length."
              ::= { dsx3ConfigEntry 6 }

          dsx3SendCode OBJECT-TYPE
                 SYNTAX  INTEGER {
                         dsx3SendNoCode(1),
                         dsx3SendLineCode(2),
                         dsx3SendPayloadCode(3),
                         dsx3SendResetCode(4),
                         dsx3SendDS1LoopCode(5),
                         dsx3SendTestPattern(6)
                         }
                 ACCESS  read-write
                 STATUS  mandatory
                 DESCRIPTION



Trunk MIB Working Group                                        [Page 15]


RFC 1407                       DS3/E3 MIB                   January 1993


                      "This variable indicates what type of code is
                      being sent across the DS3/E3 interface by the
                      device.  (These are optional for E3 interfaces.)
                      The values mean:

                         dsx3SendNoCode
                             sending looped or normal data

                         dsx3SendLineCode
                             sending a request for a line loopback

                         dsx3SendPayloadCode
                             sending a request for a payload loopback
                             (i.e., all DS1/E1s in a DS3/E3 frame)

                         dsx3SendResetCode
                             sending a loopback deactivation request

                         dsx3SendDS1LoopCode
                             requesting to loopback a particular DS1/E1
                             within a DS3/E3 frame

                         dsx3SendTestPattern
                             sending a test pattern."
                 ::= { dsx3ConfigEntry 7 }

          dsx3CircuitIdentifier OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..255))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "This variable contains the transmission vendor's
                      circuit identifier, for the purpose of
                      facilitating troubleshooting."
              ::= { dsx3ConfigEntry 8 }

          dsx3LoopbackConfig OBJECT-TYPE
                 SYNTAX  INTEGER {
                           dsx3NoLoop(1),
                           dsx3PayloadLoop(2),
                           dsx3LineLoop(3),
                           dsx3OtherLoop(4)
                         }
                 ACCESS  read-write
                 STATUS  mandatory
                 DESCRIPTION
                    "This variable represents the loopback configuration
                    of the DS3/E3 interface.



Trunk MIB Working Group                                        [Page 16]


RFC 1407                       DS3/E3 MIB                   January 1993


                    The values mean:

                    dsx3NoLoop
                      Not in the loopback state.  A device that is
                      not capable of performing a loopback on
                      the interface shall always return this as
                      it's value.

                    dsx3PayloadLoop
                      The received signal at this interface is looped
                      through the device.
                      Typically the received signal
                      is looped back for retransmission after it has
                      passed through the device's framing function.

                    dsx3LineLoop
                      The received signal at this interface does not
                      go through the device (minimum penetration) but
                      is looped back out.

                    dsx3OtherLoop
                      Loopbacks that are not defined here."
                 ::= { dsx3ConfigEntry 9 }

          dsx3LineStatus OBJECT-TYPE
              SYNTAX  INTEGER (1..1023)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                 "This variable indicates the
                 Line Status of the interface.
                 It contains loopback state information
                 and failure state information.
                 The dsx3LineStatus is a bit map represented
                 as a sum, therefore,
                 it can represent multiple failures
                 and a loopback (see dsx3LoopbackConfig object
                 for the type of loopback)
                 simultaneously.
                 The dsx3NoAlarm should be set if and only if
                 no other flag is set.

                 The various bit positions are:
                    1     dsx3NoAlarm       No alarm present
                    2     dsx3RcvRAIFailure Receiving Yellow/Remote
                          Alarm Indication
                    4     dsx3XmitRAIAlarm Transmitting Yellow/Remote
                          Alarm Indication



Trunk MIB Working Group                                        [Page 17]


RFC 1407                       DS3/E3 MIB                   January 1993


                    8     dsx3RcvAIS        Receiving AIS failure state
                   16     dsx3XmitAIS       Transmitting AIS
                   32     dsx3LOF           Receiving LOF failure state
                   64     dsx3LOS           Receiving LOS failure state
                  128     dsx3LoopbackState Looping the received signal
                  256     dsx3RcvTestCode   Receiving a Test Pattern
                  512     dsx3OtherFailure any line status not defined
                          here"
              ::= { dsx3ConfigEntry 10 }

          dsx3TransmitClockSource OBJECT-TYPE
              SYNTAX  INTEGER {
                          loopTiming(1),
                          localTiming(2),
                          throughTiming(3)
                      }
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                 "The source of Transmit Clock.
                 is derived from the recovered receive clock of
                 another DS3 interface."
              ::= { dsx3ConfigEntry 11 }


          -- the DS3/E3 Current

          -- The DS3/E3 current table contains various statistics being
          -- collected for the current 15 minute interval.

          dsx3CurrentTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3CurrentEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The DS3/E3 Current table."
              ::= { ds3 6 }

          dsx3CurrentEntry OBJECT-TYPE
              SYNTAX  Dsx3CurrentEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An entry in the DS3/E3 Current table."
              INDEX   { dsx3CurrentIndex }
              ::= { dsx3CurrentTable 1 }





Trunk MIB Working Group                                        [Page 18]


RFC 1407                       DS3/E3 MIB                   January 1993


          Dsx3CurrentEntry ::=
              SEQUENCE {
                  dsx3CurrentIndex
                      INTEGER,
                  dsx3CurrentPESs
                      Gauge,
                  dsx3CurrentPSESs
                      Gauge,
                  dsx3CurrentSEFSs
                      Gauge,
                  dsx3CurrentUASs
                      Gauge,
                  dsx3CurrentLCVs
                      Gauge,
                  dsx3CurrentPCVs
                      Gauge,
                  dsx3CurrentLESs
                      Gauge,
                  dsx3CurrentCCVs
                      Gauge,
                  dsx3CurrentCESs
                      Gauge,
                  dsx3CurrentCSESs
                      Gauge
              }

          dsx3CurrentIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3/E3 interface to which this entry is
                      applicable.  The interface identified by a
                      particular value of this index is the same
                      interface as identified by the same value an
                      dsx3LineIndex object instance."
              ::= { dsx3CurrentEntry 1 }

          dsx3CurrentPESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Errored Seconds, encountered by a DS3 interface in
                      the current 15 minute interval."
              ::= { dsx3CurrentEntry 2 }



Trunk MIB Working Group                                        [Page 19]


RFC 1407                       DS3/E3 MIB                   January 1993


          dsx3CurrentPSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Severely Errored Seconds, encountered by a DS3
                      interface in the current 15 minute interval."
              ::= { dsx3CurrentEntry 3 }

          dsx3CurrentSEFSs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Severely Errored Framing Seconds, encountered by a
                      DS3/E3 interface in the current 15 minute
                      interval."
              ::= { dsx3CurrentEntry 4 }

          dsx3CurrentUASs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Unavailable Seconds, encountered by a DS3
                      interface in the current 15 minute interval."
              ::= { dsx3CurrentEntry 5 }

          dsx3CurrentLCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of Line
                      Coding Violations encountered by a DS3/E3
                      interface in the current 15 minute interval."
              ::= { dsx3CurrentEntry 6 }

          dsx3CurrentPCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Coding Violations, encountered by a DS3 interface



Trunk MIB Working Group                                        [Page 20]


RFC 1407                       DS3/E3 MIB                   January 1993


                      in the current 15 minute interval."
              ::= { dsx3CurrentEntry 7 }

          dsx3CurrentLESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of Line Errored Seconds encountered by
                      a DS3/E3 interface in the current 15 minute
                      interval."
              ::= { dsx3CurrentEntry 8 }

          dsx3CurrentCCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Coding Violations encountered
                      by a DS3 interface in the current 15 minute
                      interval."
              ::= { dsx3CurrentEntry 9 }

          dsx3CurrentCESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Errored Seconds encountered
                      by a DS3 interface in the current 15 minute
                      interval."
              ::= { dsx3CurrentEntry 10 }

          dsx3CurrentCSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Severely Errored Seconds
                      encountered by a DS3 interface in the current 15
                      minute interval."
              ::= { dsx3CurrentEntry 11 }


          -- the DS3/E3 Interval

          -- The DS3/E3 Interval Table contains various statistics
          -- collected by each DS3/E3 Interface over the previous 24



Trunk MIB Working Group                                        [Page 21]


RFC 1407                       DS3/E3 MIB                   January 1993


          -- hours of operation.  The past 24 hours are broken into 96
          -- completed 15 minute intervals.

          dsx3IntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3IntervalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The DS3/E3 Interval table."
              ::= { ds3 7 }

          dsx3IntervalEntry OBJECT-TYPE
              SYNTAX  Dsx3IntervalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An entry in the DS3/E3 Interval table."
              INDEX   { dsx3IntervalIndex, dsx3IntervalNumber }
              ::= { dsx3IntervalTable 1 }

          Dsx3IntervalEntry ::=
              SEQUENCE {
                  dsx3IntervalIndex
                      INTEGER,
                  dsx3IntervalNumber
                      INTEGER,
                  dsx3IntervalPESs
                      Gauge,
                  dsx3IntervalPSESs
                      Gauge,
                  dsx3IntervalSEFSs
                      Gauge,
                  dsx3IntervalUASs
                      Gauge,
                  dsx3IntervalLCVs
                      Gauge,
                  dsx3IntervalPCVs
                      Gauge,
                  dsx3IntervalLESs
                      Gauge,
                  dsx3IntervalCCVs
                      Gauge,
                  dsx3IntervalCESs
                      Gauge,
                  dsx3IntervalCSESs
                      Gauge
              }




Trunk MIB Working Group                                        [Page 22]


RFC 1407                       DS3/E3 MIB                   January 1993


          dsx3IntervalIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3/E3 interface to which this entry is
                      applicable.  The interface identified by a
                      particular value of this index is the same
                      interface as identified by the same value an
                      dsx3LineIndex object instance."
              ::= { dsx3IntervalEntry 1 }

          dsx3IntervalNumber OBJECT-TYPE
              SYNTAX  INTEGER (1..96)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "A number between 1 and 96, where 1 is the most
                      recently completed 15 minute interval and 96 is
                      the least recently completed 15 minutes interval
                      (assuming that all 96 intervals are valid)."
              ::= { dsx3IntervalEntry 2 }

          dsx3IntervalPESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Errored Seconds, encountered by a DS3 interface in
                      one of the previous 96, individual 15 minute,
                      intervals."
              ::= { dsx3IntervalEntry 3 }

          dsx3IntervalPSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Severely Errored Seconds, encountered by a DS3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { dsx3IntervalEntry 4 }

          dsx3IntervalSEFSs OBJECT-TYPE
              SYNTAX  Gauge



Trunk MIB Working Group                                        [Page 23]


RFC 1407                       DS3/E3 MIB                   January 1993


              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Severely Errored Framing Seconds, encountered by a
                      DS3/E3 interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { dsx3IntervalEntry 5 }

          dsx3IntervalUASs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Unavailable Seconds, encountered by a DS3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { dsx3IntervalEntry 6 }

          dsx3IntervalLCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of Line
                      Coding Violations encountered by a DS3/E3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { dsx3IntervalEntry 7 }

          dsx3IntervalPCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Coding Violations, encountered by a DS3 interface
                      in one of the previous 96, individual 15 minute,
                      intervals."
              ::= { dsx3IntervalEntry 8 }

          dsx3IntervalLESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The number of Line Errored  Seconds  (BPVs  or



Trunk MIB Working Group                                        [Page 24]


RFC 1407                       DS3/E3 MIB                   January 1993


                   illegal  zero  sequences) encountered by a DS3/E3
                   interface in one of the previous 96, individual
                   15 minute, intervals."
              ::= { dsx3IntervalEntry 9 }

          dsx3IntervalCCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Coding Violations encountered
                      by a DS3 interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { dsx3IntervalEntry 10 }

          dsx3IntervalCESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Errored Seconds encountered
                      by a DS3 interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { dsx3IntervalEntry 11 }

          dsx3IntervalCSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Severely Errored Seconds
                      encountered by a DS3 interface in one of the
                      previous 96, individual 15 minute, intervals."
              ::= { dsx3IntervalEntry 12 }


          -- the DS3/E3 Total

          -- The DS3/E3 Total Table contains the cumulative sum of the
          -- various statistics for the 24 hour period preceding the
          -- current interval.

          dsx3TotalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3TotalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The DS3/E3 Total table.  24 hour interval."



Trunk MIB Working Group                                        [Page 25]


RFC 1407                       DS3/E3 MIB                   January 1993


              ::= { ds3 8 }

          dsx3TotalEntry OBJECT-TYPE
              SYNTAX  Dsx3TotalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An entry in the DS3/E3 Total table."
              INDEX   { dsx3TotalIndex }
              ::= { dsx3TotalTable 1 }

          Dsx3TotalEntry ::=
              SEQUENCE {
                  dsx3TotalIndex
                      INTEGER,
                  dsx3TotalPESs
                      Gauge,
                  dsx3TotalPSESs
                      Gauge,
                  dsx3TotalSEFSs
                      Gauge,
                  dsx3TotalUASs
                      Gauge,
                  dsx3TotalLCVs
                      Gauge,
                  dsx3TotalPCVs
                      Gauge,
                  dsx3TotalLESs
                      Gauge,
                  dsx3TotalCCVs
                      Gauge,
                  dsx3TotalCESs
                      Gauge,
                  dsx3TotalCSESs
                      Gauge
              }

          dsx3TotalIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3/E3 interface to which this entry is
                      applicable.  The interface identified by a
                      particular value of this index is the same
                      interface as identified by the same value an
                      dsx3LineIndex object instance."



Trunk MIB Working Group                                        [Page 26]


RFC 1407                       DS3/E3 MIB                   January 1993


              ::= { dsx3TotalEntry 1 }

          dsx3TotalPESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Errored Seconds, encountered by a DS3 interface in
                      the previous 24 hour interval"
              ::= { dsx3TotalEntry 2 }

          dsx3TotalPSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Severely Errored Seconds, encountered by a DS3
                      interface in the previous 24 hour interval."
              ::= { dsx3TotalEntry 3 }

          dsx3TotalSEFSs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Severely Errored Framing Seconds, encountered by a
                      DS3/E3 interface in the previous 24 hour
                      interval."
              ::= { dsx3TotalEntry 4 }

          dsx3TotalUASs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Unavailable Seconds, encountered by a DS3
                      interface in the previous 24 hour interval."
              ::= { dsx3TotalEntry 5 }

          dsx3TotalLCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION



Trunk MIB Working Group                                        [Page 27]


RFC 1407                       DS3/E3 MIB                   January 1993


                      "The counter associated with the number of Line
                      Coding Violations encountered by a DS3/E3
                      interface in the previous 24 hour interval."
              ::= { dsx3TotalEntry 6 }

          dsx3TotalPCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Coding Violations, encountered by a DS3 interface
                      in the previous 24 hour interval."
              ::= { dsx3TotalEntry 7 }

          dsx3TotalLESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The number of Line Errored  Seconds  (BPVs  or
                   illegal  zero  sequences) encountered by a DS3/E3
                   interface in the previous 24 hour interval."
              ::= { dsx3TotalEntry 8 }

          dsx3TotalCCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Coding Violations encountered
                      by a DS3 interface in the previous 24 hour
                      interval."
              ::= { dsx3TotalEntry 9 }

          dsx3TotalCESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Errored Seconds encountered
                      by a DS3 interface in the previous 24 hour
                      interval."
              ::= { dsx3TotalEntry 10 }

          dsx3TotalCSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only



Trunk MIB Working Group                                        [Page 28]


RFC 1407                       DS3/E3 MIB                   January 1993


              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Severely Errored Seconds
                      encountered by a DS3 interface in the previous 24
                      hour interval."
              ::= { dsx3TotalEntry 11 }


          -- The DS3 Far End Group

          -- Implementation of this group is optional for all systems
          -- that attach to a DS3 Interface.
          -- However, only C-bit Parity and SYNTRAN DS3 applications
          -- have the capability (option) of providing this information.

          -- The DS3 Far End Group consists of four tables:
          --   DS3 Far End Configuration
          --   DS3 Far End Current
          --   DS3 Far End Interval
          --   DS3 Far End Total


          -- The DS3 Far End Configuration Table contains
          -- configuration information
          -- reported in the C-bits from the remote end.

          dsx3FarEndConfigTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3FarEndConfigEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                 "The DS3 Far End Configuration table."
              ::= { ds3 9 }

          dsx3FarEndConfigEntry OBJECT-TYPE
              SYNTAX  Dsx3FarEndConfigEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                   "An entry in the DS3 Far End Configuration table."
              INDEX   { dsx3FarEndLineIndex }
              ::= { dsx3FarEndConfigTable 1 }

          Dsx3FarEndConfigEntry ::=
              SEQUENCE {
                  dsx3FarEndLineIndex
                      INTEGER,
                  dsx3FarEndEquipCode



Trunk MIB Working Group                                        [Page 29]


RFC 1407                       DS3/E3 MIB                   January 1993


                      DisplayString,
                  dsx3FarEndLocationIDCode
                      DisplayString,
                  dsx3FarEndFrameIDCode
                      DisplayString,
                  dsx3FarEndUnitCode
                      DisplayString,
                  dsx3FarEndFacilityIDCode
                      DisplayString
               }

          dsx3FarEndLineIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The index value which uniquely identifies the
                   DS3 interface
                   to which this entry is applicable.  The
                   interface identified by a particular value of
                   this index is the same interface as identified
                   by the same value an dsx3LineIndex object
                   instance."
             ::= { dsx3FarEndConfigEntry 1 }

          dsx3FarEndEquipCode OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..10))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                    "This is the Far End Equipment Identification code
                    that describes the specific piece of equipment.
                    It is sent within the Path
                    Identification Message."
              ::= { dsx3FarEndConfigEntry 2 }

          dsx3FarEndLocationIDCode OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..11))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                    "This is the Far End Location Identification code
                    that describes the specific location of the
                    equipment.
                    It is sent within the Path
                    Identification Message."
              ::= { dsx3FarEndConfigEntry 3 }




Trunk MIB Working Group                                        [Page 30]


RFC 1407                       DS3/E3 MIB                   January 1993


          dsx3FarEndFrameIDCode OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..10))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                    "This is the Far End Frame Identification code
                    that identifies where the equipment is located
                    within a building at a given location.
                    It is sent within the Path
                    Identification Message."
              ::= { dsx3FarEndConfigEntry 4 }

          dsx3FarEndUnitCode OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..6))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                    "This is the Far End code
                    that identifies the equipment location within a bay.
                    It is sent within the Path
                    Identification Message."
              ::= { dsx3FarEndConfigEntry 5 }

          dsx3FarEndFacilityIDCode OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..38))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                    "This code identifies a specific Far End DS3 path.
                    It is sent within the Path
                    Identification Message."
              ::= { dsx3FarEndConfigEntry 6 }


          -- The DS3 Far End Current

          -- The DS3 Far End Current table contains various statistics
          -- being collected for the current 15 minute interval.
          -- The statistics are collected from the far end block error
          -- code within the C-bits.

          dsx3FarEndCurrentTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3FarEndCurrentEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The DS3 Far End Current table."
              ::= { ds3 10 }



Trunk MIB Working Group                                        [Page 31]


RFC 1407                       DS3/E3 MIB                   January 1993


          dsx3FarEndCurrentEntry OBJECT-TYPE
              SYNTAX  Dsx3FarEndCurrentEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An entry in the DS3 Far End Current table."
              INDEX   { dsx3FarEndCurrentIndex }
              ::= { dsx3FarEndCurrentTable 1 }

          Dsx3FarEndCurrentEntry ::=
              SEQUENCE {
                  dsx3FarEndCurrentIndex
                      INTEGER,
                  dsx3FarEndTimeElapsed
                      INTEGER,
                  dsx3FarEndValidIntervals
                      INTEGER,
                  dsx3FarEndCurrentCESs
                      Gauge,
                  dsx3FarEndCurrentCSESs
                      Gauge,
                  dsx3FarEndCurrentCCVs
                      Gauge,
                  dsx3FarEndCurrentUASs
                      Gauge
              }

           dsx3FarEndCurrentIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3 interface
                      to which this entry is applicable.  The interface
                      identified by a particular value of this index is
                      the same interface as identified by the same value
                      an dsx3LineIndex object instance."
              ::= { dsx3FarEndCurrentEntry 1 }

          dsx3FarEndTimeElapsed OBJECT-TYPE
              SYNTAX  INTEGER (0..899)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of seconds that have elapsed since the
                      beginning of the far end current error-measurement
                      period."



Trunk MIB Working Group                                        [Page 32]


RFC 1407                       DS3/E3 MIB                   January 1993


              ::= { dsx3FarEndCurrentEntry 2 }

          dsx3FarEndValidIntervals OBJECT-TYPE
              SYNTAX  INTEGER (0..96)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of previous far end intervals for
                      which valid data was collected.  The value will be
                      96 unless the interface was brought online within
                      the last 24 hours, in which case the value will be
                      the number of complete 15 minute far end intervals
                      since the interface has been online."
              ::= { dsx3FarEndCurrentEntry 3 }

          dsx3FarEndCurrentCESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of Far
                      Far End C-bit Errored Seconds encountered by a DS3
                      interface in the current 15 minute interval."
              ::= { dsx3FarEndCurrentEntry 4 }

          dsx3FarEndCurrentCSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Far End C-bit Severely Errored Seconds
                      encountered by a DS3 interface in the current 15
                      minute interval."
              ::= { dsx3FarEndCurrentEntry 5 }

          dsx3FarEndCurrentCCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Far End C-bit Coding Violations reported via
                      the far end block error count
                      encountered by a
                      DS3 interface in the current 15 minute interval."
              ::= { dsx3FarEndCurrentEntry 6 }




Trunk MIB Working Group                                        [Page 33]


RFC 1407                       DS3/E3 MIB                   January 1993


          dsx3FarEndCurrentUASs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Far End unavailable seconds
                      encountered by a
                      DS3 interface in the current 15 minute interval."
              ::= { dsx3FarEndCurrentEntry 7 }


          -- The DS3 Far End Interval

          -- The DS3 Far End Interval Table contains various statistics
          -- collected by each DS3 interface over the previous 24
          -- hours of operation.  The past 24 hours are broken into 96
          -- completed 15 minute intervals.

          dsx3FarEndIntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3FarEndIntervalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                     "The DS3 Far End Interval table."
              ::= { ds3 11 }

          dsx3FarEndIntervalEntry OBJECT-TYPE
              SYNTAX  Dsx3FarEndIntervalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                    "An entry in the DS3 Far
                    End Interval table."
              INDEX   { dsx3FarEndIntervalIndex,
                        dsx3FarEndIntervalNumber }
              ::= { dsx3FarEndIntervalTable 1 }

          Dsx3FarEndIntervalEntry ::=
              SEQUENCE {
                   dsx3FarEndIntervalIndex
                        INTEGER,
                   dsx3FarEndIntervalNumber
                        INTEGER,
                   dsx3FarEndIntervalCESs
                        Gauge,
                   dsx3FarEndIntervalCSESs
                        Gauge,



Trunk MIB Working Group                                        [Page 34]


RFC 1407                       DS3/E3 MIB                   January 1993


                   dsx3FarEndIntervalCCVs
                        Gauge,
                   dsx3FarEndIntervalUASs
                        Gauge
              }

          dsx3FarEndIntervalIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3 interface
                      to which this entry is applicable.  The
                      interface identified by a particular value of
                      this index is the same interface as identified
                      by the same value an dsx3LineIndex object
                      instance."
              ::= { dsx3FarEndIntervalEntry 1 }

          dsx3FarEndIntervalNumber OBJECT-TYPE
             SYNTAX  INTEGER (1..96)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                    "A number between 1 and 96, where 1 is the most
                    recently completed 15 minute interval and 96 is
                    the least recently completed 15 minutes
                    interval (assuming that all 96 intervals are
                    valid)."
             ::= { dsx3FarEndIntervalEntry 2 }

          dsx3FarEndIntervalCESs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The counter associated with the number of
                      Far End C-bit Errored Seconds encountered
                      by a DS3 interface in one of the previous 96,
                      individual 15 minute, intervals."
            ::= { dsx3FarEndIntervalEntry 3 }

          dsx3FarEndIntervalCSESs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION



Trunk MIB Working Group                                        [Page 35]


RFC 1407                       DS3/E3 MIB                   January 1993


                     "The counter associated with the number of
                     Far End C-bit Severely Errored Seconds
                     encountered by a DS3 interface in one of the
                     previous 96, individual 15 minute, intervals."
            ::= { dsx3FarEndIntervalEntry 4 }

          dsx3FarEndIntervalCCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Far End C-bit Coding Violations reported via
                      the far end block error count
                      encountered by a
                      DS3 interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { dsx3FarEndIntervalEntry 5 }

          dsx3FarEndIntervalUASs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Far End unavailable seconds
                      encountered by a
                      DS3 interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { dsx3FarEndIntervalEntry 6 }


          -- The DS3 Far End Total

          -- The DS3 Far End Total Table contains the cumulative sum
          -- of the various statistics for the 24 hour period preceding
          -- the current interval.

          dsx3FarEndTotalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3FarEndTotalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The DS3 Far End Total table.  24 hour interval."
              ::= { ds3 12 }

          dsx3FarEndTotalEntry OBJECT-TYPE
              SYNTAX  Dsx3FarEndTotalEntry



Trunk MIB Working Group                                        [Page 36]


RFC 1407                       DS3/E3 MIB                   January 1993


              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An entry in the DS3 Far End Total table."
              INDEX   { dsx3FarEndTotalIndex }
              ::= { dsx3FarEndTotalTable 1 }

          Dsx3FarEndTotalEntry ::=
              SEQUENCE {
                  dsx3FarEndTotalIndex
                      INTEGER,
                  dsx3FarEndTotalCESs
                      Gauge,
                  dsx3FarEndTotalCSESs
                      Gauge,
                  dsx3FarEndTotalCCVs
                      Gauge,
                  dsx3FarEndTotalUASs
                      Gauge
              }

          dsx3FarEndTotalIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3 interface
                      to which this entry is applicable.  The interface
                      identified by a particular value of this index is
                      the same interface as identified by the same value
                      an dsx3LineIndex object instance."
              ::= { dsx3FarEndTotalEntry 1 }

          dsx3FarEndTotalCESs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The counter associated with the number of Far
                     End C-bit Errored Seconds encountered by a DS3
                     interface in the previous 24 hour interval."
             ::= { dsx3FarEndTotalEntry 2 }

          dsx3FarEndTotalCSESs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory



Trunk MIB Working Group                                        [Page 37]


RFC 1407                       DS3/E3 MIB                   January 1993


             DESCRIPTION
                     "The counter associated with the number of
                     Far End C-bit Severely Errored Seconds
                     encountered by a DS3 interface in the previous 24
                     hour interval."
             ::= { dsx3FarEndTotalEntry 3 }

          dsx3FarEndTotalCCVs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The counter associated with the number of
                     Far End C-bit Coding Violations reported via the
                     far end block error count
                     encountered by a
                     DS3 interface in the previous 24 hour interval."
             ::= { dsx3FarEndTotalEntry 4 }

          dsx3FarEndTotalUASs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The counter associated with the number of
                     Far End unavailable seconds
                     encountered by a
                     DS3 interface in the previous 24 hour interval."
             ::= { dsx3FarEndTotalEntry 5 }


          -- the DS3/E3 Fractional Group

          -- Implementation of this group is optional.  It is designed
          -- for those systems dividing a DS3/E3 into channels
          -- containing different data streams that are of local
          -- interest.

          -- The DS3/E3 fractional table identifies which DS3/E3
          -- channels associated with a CSU are being used to
          -- support a logical interface, i.e., an entry in the
          -- interfaces table from the Internet-standard MIB.

          -- For example, consider a DS3 device with 4 high speed links
          -- carrying router traffic, a feed for voice, a feed for
          -- video, and a synchronous channel for a non-routed
          -- protocol.
          -- We might describe the allocation of channels, in the



Trunk MIB Working Group                                        [Page 38]


RFC 1407                       DS3/E3 MIB                   January 1993


          -- dsx3FracTable, as follows:

          -- dsx3FracIfIndex.2. 1 = 3    dsx3FracIfIndex.2.15 = 4
          -- dsx3FracIfIndex.2. 2 = 3    dsx3FracIfIndex.2.16 = 6
          -- dsx3FracIfIndex.2. 3 = 3    dsx3FracIfIndex.2.17 = 6
          -- dsx3FracIfIndex.2. 4 = 3    dsx3FracIfIndex.2.18 = 6
          -- dsx3FracIfIndex.2. 5 = 3    dsx3FracIfIndex.2.19 = 6
          -- dsx3FracIfIndex.2. 6 = 3    dsx3FracIfIndex.2.20 = 6
          -- dsx3FracIfIndex.2. 7 = 4    dsx3FracIfIndex.2.21 = 6
          -- dsx3FracIfIndex.2. 8 = 4    dsx3FracIfIndex.2.22 = 6
          -- dsx3FracIfIndex.2. 9 = 4    dsx3FracIfIndex.2.23 = 6
          -- dsx3FracIfIndex.2.10 = 4    dsx3FracIfIndex.2.24 = 6
          -- dsx3FracIfIndex.2.11 = 4    dsx3FracIfIndex.2.25 = 6
          -- dsx3FracIfIndex.2.12 = 5    dsx3FracIfIndex.2.26 = 6
          -- dsx3FracIfIndex.2.13 = 5    dsx3FracIfIndex.2.27 = 6
          -- dsx3FracIfIndex.2.14 = 5    dsx3FracIfIndex.2.28 = 6

          -- For dsx3M23, dsx3SYNTRAN, dsx3CbitParity, and
          -- dsx3ClearChannel there are 28 legal channels, numbered 1
          -- through 28.

          -- For e3Framed there are 16 legal channels,
          -- numbered 1 through 16.  The channels (1..16) correspond
          -- directly to the equivalently numbered time-slots.

          dsx3FracTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3FracEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                 "The DS3 Fractional table."
              ::= { ds3 13 }

          dsx3FracEntry OBJECT-TYPE
               SYNTAX  Dsx3FracEntry
               ACCESS  not-accessible
               STATUS  mandatory
               DESCRIPTION
                  "An entry in the DS3 Fractional table."
              INDEX   { dsx3FracIndex, dsx3FracNumber }
              ::= { dsx3FracTable 1 }

          Dsx3FracEntry ::=
              SEQUENCE {
                  dsx3FracIndex
                      INTEGER,
                  dsx3FracNumber
                      INTEGER,



Trunk MIB Working Group                                        [Page 39]


RFC 1407                       DS3/E3 MIB                   January 1993


                  dsx3FracIfIndex
                      INTEGER
              }


          dsx3FracIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..'7fffffff'h)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                 "The index value which uniquely identifies  the
                 DS3  interface  to which this entry is applicable
                 The interface identified by a  particular
                 value  of  this  index is the same interface as
                 identified by the same value  an  dsx3LineIndex
                 object instance."
             ::= { dsx3FracEntry 1 }

          dsx3FracNumber OBJECT-TYPE
              SYNTAX  INTEGER (1..31)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                 "The channel number for this entry."
             ::= { dsx3FracEntry 2 }

          dsx3FracIfIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..'7fffffff'h)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                 "An index value that uniquely identifies an
                 interface.  The interface identified by a particular
                 value of this index is the same  interface
                 as  identified by the same value an ifIndex
                 object instance. If no interface is currently using
                 a channel, the value should be zero.  If a
                 single interface occupies more  than  one  time
                 slot,  that ifIndex value will be found in multiple
                 time slots."
             ::= { dsx3FracEntry 3 }



          END






Trunk MIB Working Group                                        [Page 40]


RFC 1407                       DS3/E3 MIB                   January 1993


5.  Acknowledgments

This document was produced by the Trunk MIB Working Groups:

                    Tracy Cox       Bellcore
                    Fred Baker      Advanced Computer Communications
                    James Watt      Newbridge
                    Bill Versteeg   Versteeg Codeworks
                    Steve Buchko    Newbridge
                    Greg Calmainis  Newbridge
                    Kaj Tesink      Bellcore
                    Al Bryenton     Bell Northern Research
                    Tom Easterday   CIC
                    John Labbe      Merit Corporation
                    Chris Sullivan  Gandalf Ltd
                    Grant Hall      Gandalf Ltd
                    John Guerrero   Digital Link
                    Rich Bradford   BBN
                    Kurt Luoto      Digital Link
                    Myron Hattig    Kentrox
                    Ed Pring        IBM
                    Larry Marks     IBM
                    Kurt Hall       Clear Communications Corp.
                    Jason Perreault Coral Network Corp.
                    Paul Farah      T3plus
                    George Kajos    Coral Network Corp.

6.  References

   [1] Cerf, V., "IAB Recommendations for the Development of Internet
       Network Management Standards", RFC 1052, NRI, April 1988.

   [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review
       Group", RFC 1109, NRI, August 1989.

   [3] Rose M., and K. McCloghrie, "Structure and Identification of
       Management Information for TCP/IP-based internets", STD 16, RFC
       1155, Performance Systems International, Hughes LAN Systems, May
       1990.

   [4] McCloghrie K., and M. Rose, "Management Information Base for
       Network Management of TCP/IP-based internets", RFC 1156, Hughes
       LAN Systems, Performance Systems International, May 1990.

   [5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
       Network Management Protocol", STD 15, RFC 1157, SNMP Research,
       Performance Systems International, Performance Systems
       International, MIT Laboratory for Computer Science, May 1990.



Trunk MIB Working Group                                        [Page 41]


RFC 1407                       DS3/E3 MIB                   January 1993


   [6] McCloghrie K., and M. Rose, Editors, "Management Information Base
       for Network Management of TCP/IP-based internets", STD 17, RFC
       1213, Performance Systems International, March 1991.

   [7] Information processing systems - Open Systems Interconnection -
       Specification of Abstract Syntax Notation One (ASN.1),
       International Organization for Standardization, International
       Standard 8824, December 1987.

   [8] Information processing systems - Open Systems Interconnection -
       Specification of Basic Encoding Rules for Abstract Notation One
       (ASN.1), International Organization for Standardization,
       International Standard 8825, December 1987.

   [9] American National Standard for Telecommunications - Digital
       Hierarchy - Electrical Interfaces, ANSI T1.102- 1987.

  [10] American National Standard for Telecommunications - Digital
       Hierarchy - Formats Specification, ANSI T1.107- 1988.

 [10a] ANSI T1.107a-1990.

  [11] American National Standard for Telecommunications - Carrier-to-
       Customer Installation - DS3 Metallic Interface, ANSI T1.404-1989.

  [12] American National Standard for Telecommunications -- Layer 1 In-
       Service Digital Transmission Performance Monitoring T1M1/92-0xx,
       T1M1.3/92-005R1, April 1992.

  [13] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
       STD 16, RFC 1212, Performance Systems International, Hughes LAN
       Systems, March 1991.

  [14] CCITT - Digital Multiplex Equipment Operating at the Third Order
       Bit Rate of 34 368 Kbit/s and the Forth Order Bit Rate of 139 264
       Kbit/s and Using Positive Justification, G.751.

  [15] European Telecommunications Standards Institute -- ETS "34M" --
       Metropolitan Area Network Physical Convergence Layer Procedure
       for 34.368 Megabits per Second, T/NA(91)18, May 1991.











Trunk MIB Working Group                                        [Page 42]


RFC 1407                       DS3/E3 MIB                   January 1993


7.  Security Considerations

   Security issues are not discussed in this memo.

8.  Authors' Addresses

   Tracy A. Cox
   Bell Communications Research
   331 Newman Springs Road
   P.O. Box 7020
   Red Bank, NJ  07701-7020

   Phone: (908) 758-2107
   EMail: tacox@mail.bellcore.com


   Kaj Tesink
   Bell Communications Research
   331 Newman Springs Road
   P.O. Box 7020
   Red Bank, NJ  07701-7020

   Phone: (908) 758-5254
   EMail: kaj@cc.bellcore.com



























Trunk MIB Working Group                                        [Page 43]


Html markup produced by rfcmarkup 1.129b, available from https://tools.ietf.org/tools/rfcmarkup/